Sungai Buloh, Selangor · Serving the Klang Valley & nationwide
Mon–Fri 10am–5:30pm · Sat 10am–1pm · 24/7 Careline +6017-965 0023
Fire Infinity
ENGINEERING SERVICES

MS 1910 · WET, DRY, PRE-ACTION & DELUGE
Fire Sprinkler System Installation & Maintenance in Selangor and Kuala Lumpur
A fire sprinkler system works automatically. When heat from a fire reaches a sprinkler head, it opens and releases water directly over the fire, controlling it at an early stage, even when nobody is there to respond.
24/7 CARELINE
What we do
✓ Installation
✓ Testing & Commissioning
✓ Maintenance
✓ Repair & Upgrade
Based in Sungai Buloh. Klang Valley daily, projects nationwide across Malaysia.
✓ Free site visit ✓ Written service report ✓ 24/7 careline
What is a fire sprinkler system and why do you need one?
Fire Infinity Engineering Services installs, tests, maintains and repairs fire sprinkler systems for commercial, industrial and residential buildings across Selangor and Kuala Lumpur. We are based in Sungai Buloh and cover the Klang Valley.
Whether you need a new sprinkler installation, a system that has been sitting without proper maintenance, or a fault that needs tracing, we start with a free site visit.
A fire sprinkler system is a network of pipes, valves and sprinkler heads connected to a water supply. Each sprinkler head reacts to heat individually. Only the heads exposed to enough heat will open, so water is released where the fire is.
In Malaysia, fire protection requirements, including extinguishment systems, are set under Part VIII of the Uniform Building By-Laws 1984 (UBBL), from by-law 225 onwards. The Tenth Schedule determines what each type of building needs.
The Malaysian Standard MS 1910 covers automatic sprinkler systems, including design, installation and maintenance.
For designated premises under the Fire Services Act 1988 (Act 341), a fire certificate (Perakuan Bomba) must be renewed every year. Operating without one is an offence under section 33, punishable by a fine up to RM50,000, jail up to 5 years, or both. A sprinkler system that is not maintained can put that certificate at risk.

Free site visit
We inspect your premises and existing system, then give you a clear written quotation. No obligation.
Types of fire sprinkler systems
Wet pipe system
Pipes are always filled with water. When a sprinkler head opens from heat, water flows immediately. The most common type for general buildings.
Dry pipe system
Pipes hold air instead of water. When a head opens, the air releases and water then flows into the pipes.
Pre-action system
Detection must happen first before water enters the pipes. This helps avoid accidental discharge, making it suitable for server rooms and archives.
Deluge system
All heads are open. When the system activates, water discharges through every head at once. Used for high-hazard areas.
Main components
✓ Sprinkler heads
✓ Pipework and fittings
✓ Control valves and alarm valves
✓ Water supply and pump set (jockey pump, electric duty pump and diesel standby pump)
✓ Connection to the fire alarm system
For rooms where water would cause damage, such as server rooms, a gas-based system may be more suitable. See our Fire Suppression System.
Our sprinkler services
01
Installation
We install sprinkler systems planned around your building's layout, occupancy and hazard level, with reference to UBBL and MS 1910.
02
Testing & Commissioning
Before handover, we test the system, including valves, alarm functions and pump operation, to make sure it responds as intended.
03
Maintenance
Sprinkler systems need regular attention to stay ready. Our maintenance covers inspection of heads, valves and pipework, pump set checks including weekly churn tests and pressure switch and flow tests, and record keeping for your files.
04
Repair & Upgrade
Common problems include corroded pipes, faulty valves, leaks and pressure drops. If your jockey pump is running frequently, it can be a sign of a leak somewhere in the system. We trace the cause, repair or replace parts, and advise on upgrades where needed.
SERVICE & MAINTENANCE
Sprinkler service & maintenance contracts
Monthly, quarterly or annual servicing to keep your sprinkler ready, with a written service report after every visit. Breakdowns are covered by our 24/7 careline.
Scheduled testing
Every device and component checked on a fixed schedule.
Written service report
Clear records after every visit for your files and inspections.
Repairs & parts
Faults found during servicing are quoted and fixed quickly.
24/7 careline
Call or WhatsApp +6017-965 0023 when something breaks.
How we work
1
Free site visit
We inspect your premises and existing system and discuss your requirements.
2
Quotation
A clear quotation based on what we found on site.
3
Installation
We carry out the installation or repair works with care to minimise disruption.
4
Testing & commissioning
The system is tested and any issues are resolved before handover.
5
Handover documents & maintenance plan
You receive the relevant documentation and a maintenance plan to keep the system ready.
Who we serve
JMB/MC and property managers
High-rise residential and mixed developments with sprinkler systems and pump rooms that need regular care.
Factories and warehouses
Large storage and production areas where sprinkler coverage is critical.
Offices and shops
Commercial buildings, shopping areas and fit-outs that need sprinkler works.
Residential
Private residential projects that need sprinkler protection.
AREAS WE COVER
Klang Valley daily. Projects nationwide.
From our base in Sungai Buloh we serve the whole Klang Valley every day, and we take on projects in every state across Malaysia.
Why choose Fire Infinity
Free site visit and consultation
We see the system before we quote.
24/7 careline
For urgent faults, leaks and pump issues.
Compliance-focused
Work planned around UBBL and MS 1910.
Related systems under one contractor
Including Fire Hydrant, Fire Hose Reel and Fire Alarm System.
FAQ
Sprinkler: frequently asked questions
Does my building need a sprinkler system?
It depends on the building type and use. UBBL's Tenth Schedule sets the requirements. We will check what applies during the free site visit.
What is the difference between wet pipe and dry pipe sprinklers?
A wet pipe system is always full of water, so it discharges immediately when a head opens. A dry pipe system holds air, and water only enters the pipes after a head opens.
Will all the sprinklers go off at once?
In wet pipe, dry pipe and pre-action systems, only the heads exposed to enough heat open. All heads discharge together only in a deluge system, which is used for high-hazard areas.
Which sprinkler system is best for a server room?
A pre-action system helps avoid accidental discharge. For many server rooms, a gas-based suppression system is also worth considering. We can advise on site.
Why is my jockey pump running so often?
A jockey pump keeps the system under pressure. If it runs frequently, there may be a leak or a pressure drop in the pipework. We can investigate and repair it.
How often should a sprinkler system be maintained?
Sprinkler systems should be maintained regularly in line with MS 1910, and pump sets should have a weekly churn test. We can set up a maintenance plan for your building.
More questions? See all fire safety FAQs or WhatsApp us.
BAHASA MELAYU
Pemasangan & Penyelenggaraan Sistem Pemercik Kebakaran di Selangor dan Kuala Lumpur
Sistem pemercik (sprinkler) berfungsi secara automatik. Apabila haba daripada kebakaran sampai ke kepala pemercik, ia akan terbuka dan menyembur air terus ke atas api, walaupun tiada sesiapa di situ.
Fire Infinity Engineering Services memasang, menguji, menyelenggara dan membaiki sistem pemercik untuk bangunan komersial, industri dan kediaman di Selangor dan Kuala Lumpur. Kami berpangkalan di Sungai Buloh.
Kenapa sistem pemercik penting?
Keperluan sistem pencegah kebakaran ditetapkan dalam Bahagian VIII Undang-Undang Kecil Bangunan Seragam 1984 (UBBL), dan Jadual Kesepuluh menentukan keperluan mengikut jenis bangunan. Standard Malaysia untuk sistem pemercik automatik ialah MS 1910, yang meliputi reka bentuk, pemasangan dan penyelenggaraan.
Bagi premis yang ditetapkan, Perakuan Bomba perlu diperbaharui setiap tahun. Sistem pemercik yang tidak diselenggara boleh menjejaskan pembaharuan ini.
Jenis sistem pemercik
Paip basah (wet pipe) – paip sentiasa berisi air. Jenis paling biasa.
Paip kering (dry pipe) – paip berisi udara sehingga kepala pemercik terbuka.
Pra-tindakan (pre-action) – pengesanan berlaku dahulu sebelum air masuk ke paip. Sesuai untuk bilik server dan arkib.
Banjir (deluge) – semua kepala terbuka serentak. Untuk kawasan berisiko tinggi.
Perkhidmatan dan proses kami
Kami menyediakan pemasangan, ujian dan pentauliahan, penyelenggaraan (termasuk ujian churn mingguan pam serta ujian suis tekanan dan aliran), dan pembaikan seperti paip berkarat, injap rosak dan kebocoran.
Set pam biasanya terdiri daripada pam jockey (mengekalkan tekanan), pam elektrik utama, dan pam diesel sebagai sandaran. Jika pam jockey kerap berjalan, itu mungkin tanda ada kebocoran atau penurunan tekanan dalam sistem.
Kami melayani JMB/MC dan pengurus hartanah, kilang dan gudang, pejabat dan kedai, serta kediaman di Sungai Buloh, Shah Alam, Petaling Jaya, Klang, Kepong, Rawang, Kuala Lumpur dan Lembah Klang, serta projek di seluruh Malaysia. Kami menyediakan talian bantuan 24/7.
Soalan Lazim
Adakah semua pemercik akan menyembur serentak?
Tidak. Hanya kepala yang terkena haba yang cukup akan terbuka, kecuali sistem deluge yang memang direka untuk membuka semua kepala.
Kenapa pam jockey saya kerap berjalan?
Pam jockey mengekalkan tekanan sistem. Jika ia kerap berjalan, mungkin ada kebocoran atau penurunan tekanan dalam paip. Kami boleh periksa dan baiki.
Adakah bangunan saya perlu sistem pemercik?
Bergantung pada jenis dan kegunaan bangunan mengikut Jadual Kesepuluh UBBL. Kami akan semak semasa lawatan tapak.
Related services

Not sure what your building needs?
We will inspect your premises and recommend the right sprinkler solution. Free, no obligation.