top of page
Fire Sprinkler System contractor Selangor

Home  /  Services  /  Fire Sprinkler System

MS 1910 · WET, DRY, PRE-ACTION & DELUGE

Fire Sprinkler System Installation & Maintenance in Selangor and Kuala Lumpur

A fire sprinkler system works automatically. When heat from a fire reaches a sprinkler head, it opens and releases water directly over the fire, controlling it at an early stage, even when nobody is there to respond.

24/7 CARELINE

What we do

✓  Installation

✓  Testing & Commissioning

✓  Maintenance

✓  Repair & Upgrade

Based in Sungai Buloh. Klang Valley daily, projects nationwide across Malaysia.

✓ Free site visit     ✓ Written service report     ✓ 24/7 careline

What is a fire sprinkler system and why do you need one?

Fire Infinity Engineering Services installs, tests, maintains and repairs fire sprinkler systems for commercial, industrial and residential buildings across Selangor and Kuala Lumpur. We are based in Sungai Buloh and cover the Klang Valley.

 

Whether you need a new sprinkler installation, a system that has been sitting without proper maintenance, or a fault that needs tracing, we start with a free site visit.

 

A fire sprinkler system is a network of pipes, valves and sprinkler heads connected to a water supply. Each sprinkler head reacts to heat individually. Only the heads exposed to enough heat will open, so water is released where the fire is.

 

In Malaysia, fire protection requirements, including extinguishment systems, are set under Part VIII of the Uniform Building By-Laws 1984 (UBBL), from by-law 225 onwards. The Tenth Schedule determines what each type of building needs.

 

The Malaysian Standard MS 1910 covers automatic sprinkler systems, including design, installation and maintenance.

 

For designated premises under the Fire Services Act 1988 (Act 341), a fire certificate (Perakuan Bomba) must be renewed every year. Operating without one is an offence under section 33, punishable by a fine up to RM50,000, jail up to 5 years, or both. A sprinkler system that is not maintained can put that certificate at risk.

Fire Sprinkler System installation by Fire Infinity

Free site visit

We inspect your premises and existing system, then give you a clear written quotation. No obligation.

Types of fire sprinkler systems

Wet pipe system

Pipes are always filled with water. When a sprinkler head opens from heat, water flows immediately. The most common type for general buildings.

Dry pipe system

Pipes hold air instead of water. When a head opens, the air releases and water then flows into the pipes.

Pre-action system

Detection must happen first before water enters the pipes. This helps avoid accidental discharge, making it suitable for server rooms and archives.

Deluge system

All heads are open. When the system activates, water discharges through every head at once. Used for high-hazard areas.

Main components

✓  Sprinkler heads

✓  Pipework and fittings

✓  Control valves and alarm valves

✓  Water supply and pump set (jockey pump, electric duty pump and diesel standby pump)

✓  Connection to the fire alarm system

For rooms where water would cause damage, such as server rooms, a gas-based system may be more suitable. See our Fire Suppression System.

Our sprinkler services

01

Installation

We install sprinkler systems planned around your building's layout, occupancy and hazard level, with reference to UBBL and MS 1910.

02

Testing & Commissioning

Before handover, we test the system, including valves, alarm functions and pump operation, to make sure it responds as intended.

03

Maintenance

Sprinkler systems need regular attention to stay ready. Our maintenance covers inspection of heads, valves and pipework, pump set checks including weekly churn tests and pressure switch and flow tests, and record keeping for your files.

04

Repair & Upgrade

Common problems include corroded pipes, faulty valves, leaks and pressure drops. If your jockey pump is running frequently, it can be a sign of a leak somewhere in the system. We trace the cause, repair or replace parts, and advise on upgrades where needed.

SERVICE & MAINTENANCE

Sprinkler service & maintenance contracts

Monthly, quarterly or annual servicing to keep your sprinkler ready, with a written service report after every visit. Breakdowns are covered by our 24/7 careline.

Scheduled testing

Every device and component checked on a fixed schedule.

Written service report

Clear records after every visit for your files and inspections.

Repairs & parts

Faults found during servicing are quoted and fixed quickly.

24/7 careline

Call or WhatsApp +6017-965 0023 when something breaks.

How we work

1

Free site visit

We inspect your premises and existing system and discuss your requirements.

2

Quotation

A clear quotation based on what we found on site.

3

Installation

We carry out the installation or repair works with care to minimise disruption.

4

Testing & commissioning

The system is tested and any issues are resolved before handover.

5

Handover documents & maintenance plan

You receive the relevant documentation and a maintenance plan to keep the system ready.

Who we serve

JMB/MC and property managers

High-rise residential and mixed developments with sprinkler systems and pump rooms that need regular care.

Factories and warehouses

Large storage and production areas where sprinkler coverage is critical.

Offices and shops

Commercial buildings, shopping areas and fit-outs that need sprinkler works.

Residential

Private residential projects that need sprinkler protection.

AREAS WE COVER

Klang Valley daily. Projects nationwide.

From our base in Sungai Buloh we serve the whole Klang Valley every day, and we take on projects in every state across Malaysia.

📍  Sungai Buloh

📍  Shah Alam

📍  Petaling Jaya

📍  Klang

📍  Kepong

📍  Rawang

📍  Kuala Lumpur

Why choose Fire Infinity

Free site visit and consultation

We see the system before we quote.

24/7 careline

For urgent faults, leaks and pump issues.

Compliance-focused

Work planned around UBBL and MS 1910.

Related systems under one contractor

Including Fire Hydrant, Fire Hose Reel and Fire Alarm System.

FAQ

Sprinkler: frequently asked questions

Does my building need a sprinkler system?

It depends on the building type and use. UBBL's Tenth Schedule sets the requirements. We will check what applies during the free site visit.

What is the difference between wet pipe and dry pipe sprinklers?

A wet pipe system is always full of water, so it discharges immediately when a head opens. A dry pipe system holds air, and water only enters the pipes after a head opens.

Will all the sprinklers go off at once?

In wet pipe, dry pipe and pre-action systems, only the heads exposed to enough heat open. All heads discharge together only in a deluge system, which is used for high-hazard areas.

Which sprinkler system is best for a server room?

A pre-action system helps avoid accidental discharge. For many server rooms, a gas-based suppression system is also worth considering. We can advise on site.

Why is my jockey pump running so often?

A jockey pump keeps the system under pressure. If it runs frequently, there may be a leak or a pressure drop in the pipework. We can investigate and repair it.

How often should a sprinkler system be maintained?

Sprinkler systems should be maintained regularly in line with MS 1910, and pump sets should have a weekly churn test. We can set up a maintenance plan for your building.

More questions? See all fire safety FAQs or WhatsApp us.

BAHASA MELAYU

Pemasangan & Penyelenggaraan Sistem Pemercik Kebakaran di Selangor dan Kuala Lumpur

Sistem pemercik (sprinkler) berfungsi secara automatik. Apabila haba daripada kebakaran sampai ke kepala pemercik, ia akan terbuka dan menyembur air terus ke atas api, walaupun tiada sesiapa di situ.

 

Fire Infinity Engineering Services memasang, menguji, menyelenggara dan membaiki sistem pemercik untuk bangunan komersial, industri dan kediaman di Selangor dan Kuala Lumpur. Kami berpangkalan di Sungai Buloh.

 

Kenapa sistem pemercik penting?

 

Keperluan sistem pencegah kebakaran ditetapkan dalam Bahagian VIII Undang-Undang Kecil Bangunan Seragam 1984 (UBBL), dan Jadual Kesepuluh menentukan keperluan mengikut jenis bangunan. Standard Malaysia untuk sistem pemercik automatik ialah MS 1910, yang meliputi reka bentuk, pemasangan dan penyelenggaraan.

 

Bagi premis yang ditetapkan, Perakuan Bomba perlu diperbaharui setiap tahun. Sistem pemercik yang tidak diselenggara boleh menjejaskan pembaharuan ini.

 

Jenis sistem pemercik

 

  • Paip basah (wet pipe) – paip sentiasa berisi air. Jenis paling biasa.

  • Paip kering (dry pipe) – paip berisi udara sehingga kepala pemercik terbuka.

  • Pra-tindakan (pre-action) – pengesanan berlaku dahulu sebelum air masuk ke paip. Sesuai untuk bilik server dan arkib.

  • Banjir (deluge) – semua kepala terbuka serentak. Untuk kawasan berisiko tinggi.

 

Perkhidmatan dan proses kami

 

Kami menyediakan pemasangan, ujian dan pentauliahan, penyelenggaraan (termasuk ujian churn mingguan pam serta ujian suis tekanan dan aliran), dan pembaikan seperti paip berkarat, injap rosak dan kebocoran.

 

Set pam biasanya terdiri daripada pam jockey (mengekalkan tekanan), pam elektrik utama, dan pam diesel sebagai sandaran. Jika pam jockey kerap berjalan, itu mungkin tanda ada kebocoran atau penurunan tekanan dalam sistem.

 

Kami melayani JMB/MC dan pengurus hartanah, kilang dan gudang, pejabat dan kedai, serta kediaman di Sungai Buloh, Shah Alam, Petaling Jaya, Klang, Kepong, Rawang, Kuala Lumpur dan Lembah Klang, serta projek di seluruh Malaysia. Kami menyediakan talian bantuan 24/7.

Soalan Lazim

Adakah semua pemercik akan menyembur serentak?

Tidak. Hanya kepala yang terkena haba yang cukup akan terbuka, kecuali sistem deluge yang memang direka untuk membuka semua kepala.

Kenapa pam jockey saya kerap berjalan?

Pam jockey mengekalkan tekanan sistem. Jika ia kerap berjalan, mungkin ada kebocoran atau penurunan tekanan dalam paip. Kami boleh periksa dan baiki.

Adakah bangunan saya perlu sistem pemercik?

Bergantung pada jenis dan kegunaan bangunan mengikut Jadual Kesepuluh UBBL. Kami akan semak semasa lawatan tapak.

Related services

Fire Hydrant & Pump Set

Fire Hydrant & Pump Set

Hydrants, pump sets and underground main leak repair.

Fire Alarm System

Fire Alarm System

Panels, detectors, call points and Bomba monitoring link.

Fire Hose Reel System

Fire Hose Reel System

Hose reel installation, testing and repair.

Not sure what your building needs?

We will inspect your premises and recommend the right sprinkler solution. Free, no obligation.

bottom of page