Fire Suppression Systems in Selangor and Kuala Lumpur – FM-200, Novec 1230, CO2, Inert Gas & Wet Chemical
Some rooms cannot be protected with water. A server room, a switch room or an archive full of records can be destroyed by sprinkler water just as surely as by fire. A commercial kitchen hood full of hot oil needs a different approach again.
24/7 CARELINE
What we do
✓ Installation
✓ Testing & Commissioning
✓ Maintenance
✓ Repair & Upgrade
Based in Sungai Buloh. Klang Valley daily, projects nationwide across Malaysia.
✓ Free site visit ✓ Written service report ✓ 24/7 careline
What Is a Fire Suppression System and Why Do You Need It?
A fire suppression system is designed for exactly these risks. Fire Infinity Engineering Services installs, tests, maintains and repairs fire suppression systems across Selangor and Kuala Lumpur, including FM-200, Novec 1230, inert gas, CO2 and wet chemical kitchen systems.
We are based in Sungai Buloh. Every project starts with a free site visit, so we can understand the room, the risk and the equipment you need to protect.
A fire suppression system detects a fire in a specific room or piece of equipment and automatically discharges an extinguishing agent to put it out. Unlike sprinklers, gas-based systems leave no water damage, which makes them the preferred choice for high-value electrical and data equipment.
Relevant requirements and standards include:
UBBL 1984, Part VIII – covers fire detection and extinguishment (by-laws from 225 onwards), with the Tenth Schedule setting requirements by building type.
MS ISO 14520 – the standard for gaseous fire-extinguishing agents, including HFC-227ea (FM-200), IG-541 and IG-55.
Fire Services Act 1988 (Act 341) – designated premises must hold a valid fire certificate (Perakuan Bomba), renewed every year. Operating without one is an offence under section 33, with a fine of up to RM50,000, up to 5 years in jail, or both.
Keeping your suppression system tested and maintained helps protect your equipment and supports a smooth Perakuan Bomba renewal. We recommend starting the renewal at least 30 days before expiry.

Types of Fire Suppression Systems
A typical system includes agent cylinders, discharge pipework and nozzles, fire detectors, a suppression control panel, manual release and abort switches, and warning signs and alarms.
FM-200 (HFC-227ea)
A clean agent for server rooms, data centres, control rooms, switch rooms and archives.
Novec 1230 (FK-5-1-12)
A clean agent used for the same kinds of spaces: server rooms, data centres, control and switch rooms, and archives.
Inert gas (IG-541 / IG-55)
Suppression using inert gas mixtures, also suited to server rooms, data centres, control rooms and archives.
CO2 (carbon dioxide)
For unoccupied electrical rooms, transformer rooms and paint lines. CO2 total flooding carries an asphyxiation risk and is only for spaces that are not occupied by people.
Wet chemical kitchen suppression
For commercial kitchen hoods, where cooking oil and fat fires need a dedicated system.
Our Suppression Services
01
Installation
We supply and install complete suppression systems, matched to the room, the hazard and whether the space is occupied. This includes cylinders, pipework, nozzles, detection and control panel.
02
Testing & Commissioning
Before handover, we test detection, control panel logic, alarms and release functions, and confirm the system is correctly connected to your building's fire alarm. Results are documented for your records.
03
Maintenance
Suppression systems need regular inspection to stay ready. We check cylinder condition and pressure, detectors, control panels, nozzles and pipework, and provide service records for your Bomba inspection.
04
Repair & Upgrade
We repair faulty detectors, panels and release mechanisms, refill or replace cylinders after a discharge, and upgrade older systems when rooms are expanded or repurposed.
SERVICE & MAINTENANCE
Suppression service & maintenance contracts
Monthly, quarterly or annual servicing to keep your suppression ready, with a written service report after every visit. Breakdowns are covered by our 24/7 careline.
Scheduled testing
Every device and component checked on a fixed schedule.
Written service report
Clear records after every visit for your files and inspections.
Repairs & parts
Faults found during servicing are quoted and fixed quickly.
24/7 careline
Call or WhatsApp +6017-965 0023 when something breaks.
How we work
1
Free site visit
We assess the room, its equipment, its occupancy and your fire risk.
2
Quotation
A clear written quotation with the recommended agent and scope.
3
Installation
Carried out with care around live equipment and minimal downtime.
4
Testing & commissioning
Full function testing before handover.
5
Handover documents & maintenance plan
Records, operating guidance and a maintenance schedule.
Who we serve
JMB/MC and property managers
Switch rooms, transformer rooms and building control rooms
Factories and warehouses
Electrical rooms, paint lines, control rooms and records stores
Offices and shops
Server rooms, data rooms and commercial kitchens in F&B outlets
Residential
Shared electrical and control rooms in residential developments
AREAS WE COVER
Klang Valley daily. Projects nationwide.
From our base in Sungai Buloh we serve the whole Klang Valley every day, and we take on projects in every state across Malaysia.
Why choose Fire Infinity
Free site visit and consultation
We recommend the agent that suits your room, not the most expensive option.
24/7 careline
For faults, alarms or a discharge that needs urgent attention.
Compliance-focused
Systems planned around UBBL and MS ISO 14520, with proper documentation.
Safety-first advice
We will tell you plainly when an agent such as CO2 is not suitable for an occupied space.
FAQ
Suppression: frequently asked questions
What is the difference between FM-200 and Novec 1230?
Both are clean agents used to protect server rooms, data centres, control rooms and archives. FM-200 is HFC-227ea; Novec 1230 is FK-5-1-12. We help you choose the right one during the site visit.
Can CO2 suppression be used in an office or server room where people work?
No. CO2 total flooding carries an asphyxiation risk and should only be used in unoccupied spaces such as electrical rooms, transformer rooms and paint lines.
Will a suppression system damage my servers?
Clean agent and inert gas systems are used in server rooms and data centres because they do not leave water damage like sprinklers can.
Do commercial kitchens need a special system?
Cooking oil and fat fires need wet chemical protection. A wet chemical suppression system protects the kitchen hood, and a wet chemical extinguisher is the correct portable choice for oil fires.
What happens after a suppression system discharges?
The system must be inspected, cylinders refilled or replaced, and the system recommissioned before the room is fully protected again. Contact our 24/7 careline.
How often should a suppression system be maintained?
Suppression systems should be inspected and maintained regularly by a qualified contractor. We provide a maintenance plan with every installation.
More questions? See all fire safety FAQs or WhatsApp us.
BAHASA MELAYU
Sistem Pencegah Kebakaran (Suppression) di Selangor dan Kuala Lumpur
Soalan Lazim
Apa beza FM-200 dan Novec 1230?
Kedua-duanya agen bersih untuk bilik server, pusat data dan arkib. Kami bantu anda pilih yang sesuai semasa lawatan tapak.
Bilik server, bilik suis atau arkib dokumen tidak sesuai dilindungi dengan air – air pemercik boleh merosakkan peralatan sama teruk seperti api. Dapur komersial pula memerlukan perlindungan khas untuk minyak masak yang terbakar.
Fire Infinity Engineering Services memasang, menguji, menyelenggara dan membaiki sistem pencegah kebakaran jenis gas dan bahan kimia basah di Selangor dan Kuala Lumpur. Kami berpangkalan di Sungai Buloh dan menawarkan lawatan tapak percuma.
Jenis Sistem Pencegah Kebakaran
FM-200 (HFC-227ea) – untuk bilik server, pusat data, bilik kawalan, bilik suis dan arkib.
Novec 1230 (FK-5-1-12) – agen bersih untuk ruang yang sama seperti FM-200.
Gas lengai IG-541 / IG-55 – juga sesuai untuk bilik server, pusat data dan arkib.
CO2 – untuk bilik elektrik, bilik transformer dan laluan cat yang tidak berpenghuni sahaja. CO2 boleh menyebabkan lemas, jadi ia tidak boleh digunakan di ruang yang ada orang.
Kimia basah (wet chemical) – untuk hud dapur komersial.
Kelebihan utama sistem gas ialah ia tidak meninggalkan kerosakan air pada peralatan. Sistem gas dikawal oleh MS ISO 14520, manakala keperluan bangunan ditetapkan dalam UBBL 1984 Bahagian VIII.
Perkhidmatan Kami
Pemasangan – silinder, paip, muncung, pengesan dan panel kawalan, dipadankan dengan bilik dan risiko.
Ujian & pentauliahan – ujian pengesan, panel, penggera dan fungsi pelepasan.
Penyelenggaraan – pemeriksaan berkala silinder, pengesan, panel dan paip, berserta rekod servis.
Pembaikan & naik taraf – baiki kerosakan, isi semula atau ganti silinder selepas pelepasan, dan naik taraf sistem lama.
Siapa Kami Bantu
JMB/MC dan pengurus hartanah, kilang dan gudang, pejabat, kedai dan premis F&B, serta pembangunan kediaman – di Sungai Buloh, Shah Alam, Petaling Jaya, Klang, Kepong, Rawang, Kuala Lumpur dan Lembah Klang, serta projek di seluruh Malaysia. Kami juga ada careline 24/7.
Bolehkah sistem CO2 dipasang di pejabat yang ada pekerja?
Tidak. CO2 hanya untuk ruang tidak berpenghuni seperti bilik elektrik dan bilik transformer kerana risiko lemas.
Apa perlu dibuat selepas sistem melepaskan gas?
Sistem perlu diperiksa, silinder diisi semula atau diganti, dan sistem ditauliahkan semula. Hubungi careline 24/7 kami.